Products

Dog suPAR(soluble Plasminogen Activator, Urokinase Receptor) ELISA Kit
One-click to copy product information
ELK9083
Size: Price:
48 T $320.00
96 T $458.00

Overview

Product name: Dog suPAR(soluble Plasminogen Activator, Urokinase Receptor) ELISA Kit
Reactivity: Dog
Alternative Names: CD87; PLAUR; PLAU-R; U-PAR; URKR; Monocyte Activation Antigen Mo3
Assay Type: Sandwich
Sensitivity: 35 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample type: serum, plasma, tissue homogenates and other biological fluids
Assay length: 3.5h
Research Area: Tumor immunity;Hematology;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Dog suPAR. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Dog suPAR. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Dog suPAR, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Dog suPAR in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (pg/mL) OD Corrected OD
5000.00 2.168 2.087
2500.00 1.663 1.582
1250.00 1.139 1.058
625.00 0.897 0.816
312.50 0.655 0.574
156.25 0.365 0.284
78.13 0.215 0.134
0.00 0.081 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant suPAR and the recovery rates were calculated by comparing the measured value to the expected amount of suPAR in samples.
Matrix Recovery range Average
serum(n=5) 83-97% 90%
EDTA plasma(n=5) 80-97% 88%
Heparin plasma(n=5) 83-95% 89%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of suPAR and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 81-103% 89-101% 81-98% 93-102%
EDTA plasma(n=5) 78-92% 87-98% 80-93% 87-101%
Heparin plasma(n=5) 89-102% 85-98% 93-102% 81-96%