Products

Mouse PAFAH2(Platelet Activating Factor Acetylhydrolase 2) ELISA Kit
One-click to copy product information
ELK7007
Size: Price:
48 T $320.00
96 T $458.00

Overview

Product name: Mouse PAFAH2(Platelet Activating Factor Acetylhydrolase 2) ELISA Kit
Reactivity: Mouse
Alternative Names: SD-PLA2; Serine-dependent phospholipase A2; Platelet-activating factor acetylhydrolase 2, cytoplasmic
Assay Type: Sandwich
Sensitivity: 13.5 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample type: Serum, plasma, tissue homogenates and other biological fluids.
Assay length: 3.5h
Research Area: Enzyme & Kinase;Metabolic pathway;Hematology;
Uniprot ID: Q8VDG7
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse PAFAH2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse PAFAH2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse PAFAH2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse PAFAH2 in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (pg/mL) OD Corrected OD
2000.00 2.079 1.998
1000.00 1.647 1.566
500.00 1.243 1.162
250.00 0.975 0.894
125.00 0.593 0.512
62.50 0.363 0.282
31.25 0.288 0.207
0.00 0.081 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant PAFAH2 and the recovery rates were calculated by comparing the measured value to the expected amount of PAFAH2 in samples.
Matrix Recovery range Average
serum(n=5) 82-95% 88%
EDTA plasma(n=5) 94-105% 98%
Heparin plasma(n=5) 94-107% 100%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PAFAH2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 86-93% 91-105% 87-98% 89-94%
EDTA plasma(n=5) 87-96% 85-97% 85-94% 87-96%
Heparin plasma(n=5) 85-97% 87-96% 85-96% 85-95%