| 48 T | $320.00 |
| 96 T | $458.00 |
| 96 T*5 | $1947.00 |
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 10.00 | 2.075 | 1.977 |
| 5.00 | 1.593 | 1.495 |
| 2.50 | 1.157 | 1.059 |
| 1.25 | 0.895 | 0.797 |
| 0.63 | 0.556 | 0.458 |
| 0.32 | 0.339 | 0.241 |
| 0.16 | 0.165 | 0.067 |
| 0.00 | 0.098 | 0.000 |

Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 78-93% | 85% |
| EDTA plasma(n=5) | 87-99% | 93% |
| Heparin plasma(n=5) | 90-103% | 96% |
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 85-94% | 87-99% | 85-101% | 79-90% |
| EDTA plasma(n=5) | 86-95% | 93-103% | 85-94% | 87-101% |
| Heparin plasma(n=5) | 85-94% | 90-99% | 95-102% | 82-90% |