| 48 T | $412.00 | 
| 96 T | $588.00 | 
| 96 T*5 | $2499.00 | 
| Concentration (ng/mL) | OD | Corrected OD | 
|---|---|---|
| 100.00 | 1.849 | 1.766 | 
| 50.00 | 1.487 | 1.404 | 
| 25.00 | 0.976 | 0.893 | 
| 12.50 | 0.872 | 0.789 | 
| 6.25 | 0.541 | 0.458 | 
| 3.13 | 0.324 | 0.241 | 
| 1.57 | 0.211 | 0.128 | 
| 0.00 | 0.083 | 0.000 | 

Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
| Matrix | Recovery range | Average | 
|---|---|---|
| serum(n=5) | 87-99% | 93% | 
| EDTA plasma(n=5) | 80-93% | 86% | 
| Heparin plasma(n=5) | 93-107% | 100% | 
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 | 
|---|---|---|---|---|
| serum(n=5) | 87-95% | 85-98% | 82-97% | 92-101% | 
| EDTA plasma(n=5) | 85-98% | 81-96% | 87-98% | 92-103% | 
| Heparin plasma(n=5) | 81-93% | 86-98% | 91-103% | 82-95% |