| 48 T | $320.00 |
| 96 T | $458.00 |
| 96 T*5 | $1947.00 |
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 100.00 | 2.060 | 1.967 |
| 50.00 | 1.597 | 1.504 |
| 25.00 | 1.244 | 1.151 |
| 12.50 | 0.842 | 0.749 |
| 6.25 | 0.577 | 0.484 |
| 3.13 | 0.330 | 0.237 |
| 1.56 | 0.229 | 0.136 |
| 0.00 | 0.093 | 0.000 |

Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 88-106% | 97% |
| EDTA plasma(n=5) | 87-126% | 107% |
| Heparin plasma(n=5) | 89-109% | 99% |
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 89-104% | 87-107% | 84-119% | 82-113% |
| EDTA plasma(n=5) | 94-110% | 89-117% | 93-105% | 82-100% |
| Heparin plasma(n=5) | 86-93% | 89-110% | 91-104% | 94-115% |