Products

Rat PIICP(Procollagen II C-Terminal Propeptide) ELISA Kit
One-click to copy product information
ELK2409
Size: Price:
48 T $320.00
96 T $458.00

Overview

Product name: Rat PIICP(Procollagen II C-Terminal Propeptide) ELISA Kit
Reactivity: Rat
Alternative Names: P2CP; C-Propeptide Of Type II Procollagen; Procollagen II Carboxy Terminal Propeptide
Assay Type: Sandwich
Sensitivity: 12.3 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample type: Serum, plasma and other biological fluids
Assay length: 3.5h
Research Area: Infection immunity;Bone metabolism;Rheumatology;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat PIICP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat PIICP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat PIICP, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat PIICP in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (pg/mL) OD Corrected OD
2000.00 1.964 1.871
1000.00 1.616 1.523
500.00 1.128 1.035
250.00 0.901 0.808
125.00 0.593 0.500
62.50 0.368 0.275
31.25 0.199 0.106
0.00 0.093 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant PIICP and the recovery rates were calculated by comparing the measured value to the expected amount of PIICP in samples.
Matrix Recovery range Average
serum(n=5) 82-97% 89%
EDTA plasma(n=5) 80-95% 87%
Heparin plasma(n=5) 86-99% 92%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PIICP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-102% 78-92% 87-98% 95-102%
EDTA plasma(n=5) 79-97% 96-104% 85-93% 89-97%
Heparin plasma(n=5) 85-94% 87-96% 92-105% 89-102%