Products

Rat DHEA-S(Dehydroepiandrosterone sulfate) ELISA Kit
One-click to copy product information
ELK11774
Size: Price:
48 T $320.00
96 T $458.00
96 T*5 $1947.00

Overview

Product name: Rat DHEA-S(Dehydroepiandrosterone sulfate) ELISA Kit
Reactivity: Rat
Alternative Names: Androstenolone sulfate; Prasterone sulfate; Androst-5-en-3β-ol-17-one 3β-sulfate
Assay Type: Competitive Inhibition
Sensitivity: 4.25 ng/mL
Standard: 400 ng/mL
Detection Range: 6.25-400 ng/mL
Sample Type: Serum, plasma and other biological fluids.
Assay Length: 2h
Research Area: Endocrinology;Reproductive science;Hormone metabolism;Rheumatology;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Rat DHEA-S. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat DHEA-S. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat DHEA-S in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (ng/mL) OD Corrected OD
400.00 0.213
200.00 0.352
100.00 0.586
50.00 0.856
25.00 1.197
12.50 1.522
6.25 1.775
0.00 2.132

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant DHEA-S and the recovery rates were calculated by comparing the measured value to the expected amount of DHEA-S in samples.
Matrix Recovery range Average
serum(n=5) 89-97% 93%
EDTA plasma(n=5) 95-105% 100%
Heparin plasma(n=5) 95-106% 101%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of DHEA-S and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-102% 90-103% 86-95% 79-90%
EDTA plasma(n=5) 85-95% 82-96% 84-91% 84-91%
Heparin plasma(n=5) 93-105% 92-102% 78-86% 90-101%