Products

Simian HMGB-1(High Mobility Group Protein B1) ELISA Kit
One-click to copy product information
ELK11605
Size: Price:
48 T $412.00
96 T $588.00
96 T*5 $2499.00

Overview

Product name: Simian HMGB-1(High Mobility Group Protein B1) ELISA Kit
Reactivity: Simian
Alternative Names: HMGB1; HMG3; SBP1; Sulfoglucuronyl Carbohydrate Binding Protein; Amphoterin; High Mobility Group Box 1 Protein; HMG1; High Mobility Group Protein 1
Assay Type: Sandwich
Sensitivity: 0.064 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: serum, plasma and other biological fluids
Assay Length: 3.5h
Research Area: Infection immunity;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Simian HMGB-1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Simian HMGB-1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Simian HMGB-1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Simian HMGB-1 in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (ng/mL) OD Corrected OD
10.00 2.391 2.295
5.00 1.757 1.661
2.50 1.223 1.127
1.25 0.872 0.776
0.63 0.595 0.499
0.31 0.331 0.235
0.16 0.198 0.102
0.00 0.096 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant HMGB-1 and the recovery rates were calculated by comparing the measured value to the expected amount of HMGB-1 in samples.
Matrix Recovery range Average
serum(n=5) 93-107% 100%
EDTA plasma(n=5) 90-105% 97%
Heparin plasma(n=5) 83-98% 90%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HMGB-1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-98% 85-100% 84-99% 85-97%
EDTA plasma(n=5) 87-98% 85-92% 79-96% 89-100%
Heparin plasma(n=5) 85-96% 92-102% 81-93% 85-97%