| 48 T | $412.00 | 
| 96 T | $588.00 | 
| 96 T*5 | $2499.00 | 
| Concentration (µg/mL) | OD | Corrected OD | 
|---|---|---|
| 500.00 | 2.132 | 2.037 | 
| 250.00 | 1.628 | 1.533 | 
| 125.00 | 1.096 | 1.001 | 
| 62.50 | 0.963 | 0.868 | 
| 31.25 | 0.595 | 0.500 | 
| 15.63 | 0.331 | 0.236 | 
| 7.82 | 0.235 | 0.140 | 
| 0.00 | 0.095 | 0.000 | 

Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
| Matrix | Recovery range | Average | 
|---|---|---|
| serum(n=5) | 85-99% | 92% | 
| EDTA plasma(n=5) | 93-107% | 100% | 
| Heparin plasma(n=5) | 87-99% | 93% | 
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 | 
|---|---|---|---|---|
| serum(n=5) | 89-103% | 79-92% | 88-97% | 85-97% | 
| EDTA plasma(n=5) | 95-106% | 88-103% | 81-98% | 93-102% | 
| Heparin plasma(n=5) | 90-99% | 95-106% | 87-101% | 82-97% |