| 48 T | $320.00 |
| 96 T | $458.00 |
| 96 T*5 | $1947.00 |
| Concentration (µg/mL) | OD | Corrected OD |
|---|---|---|
| 10.00 | 2.079 | 1.986 |
| 5.00 | 1.556 | 1.463 |
| 2.50 | 1.128 | 1.035 |
| 1.25 | 0.901 | 0.808 |
| 0.63 | 0.614 | 0.521 |
| 0.32 | 0.256 | 0.163 |
| 0.16 | 0.156 | 0.063 |
| 0.00 | 0.093 | 0.000 |

Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 80-93% | 86% |
| EDTA plasma(n=5) | 93-107% | 100% |
| Heparin plasma(n=5) | 87-99% | 93% |
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 85-90% | 83-96% | 95-102% | 88-95% |
| EDTA plasma(n=5) | 86-94% | 93-102% | 89-97% | 85-94% |
| Heparin plasma(n=5) | 79-96% | 85-99% | 79-93% | 89-97% |