Products

Cattle NEFL(Neurofilament, Light Polypeptide) ELISA Kit
One-click to copy product information
ELK10024
Size: Price:
48 T $320.00
96 T $458.00

Overview

Product name: Cattle NEFL(Neurofilament, Light Polypeptide) ELISA Kit
Reactivity: Cattle
Alternative Names: CMT1F; CMT2E; NF-L; NF68; NFL; 68 kDa neurofilament protein; Neurofilament triplet L protein
Assay Type: Sandwich
Sensitivity: 6.1 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample type: serum, plasma, cerebrospinal fluid and other biological fluids
Assay length: 3.5h
Research Area: Neuro science;
Uniprot ID: P02548
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Cattle NEFL. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Cattle NEFL. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Cattle NEFL, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Cattle NEFL in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (pg/mL) OD Corrected OD
1000.00 2.258 2.170
500.00 1.708 1.620
250.00 1.211 1.123
125.00 0.933 0.845
62.50 0.538 0.450
31.25 0.387 0.299
15.63 0.175 0.087
0.00 0.088 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant NEFL and the recovery rates were calculated by comparing the measured value to the expected amount of NEFL in samples.
Matrix Recovery range Average
serum(n=5) 81-97% 89%
EDTA plasma(n=5) 81-95% 88%
Heparin plasma(n=5) 90-107% 98%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of NEFL and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 79-96% 91-103% 87-98%
EDTA plasma(n=5) 92-104% 82-96% 83-96% 79-93%
Heparin plasma(n=5) 81-93% 86-98% 84-98% 78-102%