| 48 T | $265.00 |
| 96 T | $376.00 |
| 96 T*5 | $1598.00 |
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 300.00 | 0.182 | |
| 150.00 | 0.387 | |
| 75.00 | 0.692 | |
| 37.50 | 0.823 | |
| 18.75 | 1.157 | |
| 9.38 | 1.511 | |
| 4.69 | 1.697 | |
| 0.00 | 2.157 |

Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 93-107% | 100% |
| EDTA plasma(n=5) | 87-99% | 93% |
| Heparin plasma(n=5) | 92-107% | 99% |
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 87-99% | 85-96% | 87-101% | 89-102% |
| EDTA plasma(n=5) | 82-94% | 85-96% | 78-90% | 91-99% |
| Heparin plasma(n=5) | 83-96% | 92-104% | 89-101% | 85-97% |