Products

Human CA15-3(Carbonhydrate Antigen 15-3) Microsample ELISA Kit
One-click to copy product information
ELK0245MS
Size: Price:
48 T $320.00
96 T $458.00
96 T*5 $1947.00

Overview

Product name: Human CA15-3(Carbonhydrate Antigen 15-3) Microsample ELISA Kit
Reactivity: Human
Alternative Names: CA15-3
Assay Type: Sandwich
Sensitivity: 0.49 U/mL
Standard: 100 U/mL
Detection Range: 1.57-100 U/mL
Sample Type: serum, plasma and other biological fluids
Assay Length: 3.5h
Research Area: Tumor immunity;Infection immunity;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CA15-3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CA15-3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CA15-3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CA15-3 in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (U/mL) OD Corrected OD
100.00 2.174 2.088
50.00 1.613 1.527
25.00 1.232 1.146
12.50 0.824 0.738
6.25 0.588 0.502
3.13 0.373 0.287
1.56 0.138 0.052
0.00 0.086 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant CA15-3 and the recovery rates were calculated by comparing the measured value to the expected amount of CA15-3 in samples.
Matrix Recovery range Average
serum(n=5) 82-111% 97%
EDTA plasma(n=5) 92-117% 105%
Heparin plasma(n=5) 86-118% 102%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CA15-3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 83-115% 88-110% 90-96% 81-89%
EDTA plasma(n=5) 89-117% 90-115% 81-100% 84-96%
Heparin plasma(n=5) 88-119% 88-114% 93-113% 90-113%

Product Components