Products

Human CD209(CD209 Antigen) ELISA Kit
ELK0109
Size: Price:
48 T $320.00
96 T $458.00

Overview

Product name: Human CD209(CD209 Antigen) ELISA Kit
Reactivity: Human
Alternative Names: C-type lectin domain family 4 member L; Dendritic cell-specific ICAM-3-grabbing non-integrin 1; DC-SIGN; DC-SIGN1
Assay Type: Sandwich
Sensitivity: 26.3 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample Type: Serum, plasma, tissue homogenates
Assay Length: 3.5h
Research Area: CD & Adhesion molecule;Tumor immunity;Reproductive science;
Uniprot ID: Q9NNX6
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CD209. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CD209. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CD209, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CD209 in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (pg/mL) OD Corrected OD
5000.00 2.164 2.070
2500.00 1.394 1.300
1250.00 1.027 0.933
625.00 0.866 0.772
312.50 0.518 0.424
156.25 0.318 0.224
78.13 0.197 0.103
0.00 0.094 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant CD209 and the recovery rates were calculated by comparing the measured value to the expected amount of CD209 in samples.
Matrix Recovery range Average
serum(n=5) 80-95% 87%
EDTA plasma(n=5) 90-105% 97%
Heparin plasma(n=5) 86-99% 92%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CD209 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 92-105% 82-92% 86-94% 81-95%
EDTA plasma(n=5) 91-97% 86-92% 79-93% 89-106%
Heparin plasma(n=5) 95-104% 87-96% 89-101% 82-90%