Products

Dog ACVA(Activin A) ELISA Kit
ELK9720
Size: Price:
48 T $320.00
96 T $458.00

Overview

Product name: Dog ACVA(Activin A) ELISA Kit
Reactivity: Dog
Alternative Names: ACV-A; Activin Beta A Beta A Homodimer
Assay Type: Competitive Inhibition
Sensitivity: 4.63 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 2h
Research Area: Endocrinology;Reproductive science;Hormone metabolism;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Dog ACVA protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Dog ACVA. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Dog ACVA in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (pg/mL) OD Corrected OD
1000.00 0.179
500.00 0.386
250.00 0.655
125.00 0.997
62.50 1.197
31.25 1.596
15.63 1.861
0.00 2.375

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant ACVA and the recovery rates were calculated by comparing the measured value to the expected amount of ACVA in samples.
Matrix Recovery range Average
serum(n=5) 82-94% 88%
EDTA plasma(n=5) 93-107% 100%
Heparin plasma(n=5) 81-97% 89%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ACVA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-103% 83-94% 92-105% 89-97%
EDTA plasma(n=5) 87-95% 83-96% 92-102% 82-93%
Heparin plasma(n=5) 83-97% 87-98% 89-102% 98-102%