Products

Mouse MYB(Transcriptional activator Myb) ELISA Kit
ELK9693
Size: Price:
48 T $320.00
96 T $458.00

Overview

Product name: Mouse MYB(Transcriptional activator Myb) ELISA Kit
Reactivity: Mouse
Alternative Names: MYB; Transcriptional activator Myb; Proto-oncogene c-Myb
Assay Type: Sandwich
Sensitivity: 0.063 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Epigenetics and Nuclear Signaling
Uniprot ID: P06876
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse MYB. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse MYB. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse MYB, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse MYB in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (ng/mL) OD Corrected OD
10.00 2.126 2.043
5.00 1.663 1.580
2.50 1.251 1.168
1.25 0.828 0.745
0.63 0.532 0.449
0.32 0.368 0.285
0.16 0.267 0.184
0.00 0.083 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant MYB and the recovery rates were calculated by comparing the measured value to the expected amount of MYB in samples.
Matrix Recovery range Average
serum(n=5) 80-97% 88%
EDTA plasma(n=5) 82-95% 88%
Heparin plasma(n=5) 96-107% 102%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MYB and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-96% 87-98% 93-102% 85-93%
EDTA plasma(n=5) 87-96% 97-105% 79-97% 86-92%
Heparin plasma(n=5) 81-93% 89-97% 85-94% 97-106%