Products

Human LONP1(Lon protease homolog, mitochondrial) ELISA Kit
ELK9460
Size: Price:
48 T $265.00
96 T $376.00

Overview

Product name: Human LONP1(Lon protease homolog, mitochondrial) ELISA Kit
Reactivity: Human
Alternative Names: Lon protease homolog, mitochondrial; LONHs; Lon protease-like protein; LONP; Mitochondrial ATP-dependent protease Lon; Serine protease 15; PRSS15; LONP1
Assay Type: Sandwich
Sensitivity: 11.9 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Epigenetics and Nuclear Signaling; Metabolism; Cancer
Uniprot ID: P36776
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human LONP1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human LONP1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human LONP1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human LONP1 in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (pg/mL) OD Corrected OD
2000.00 2.131 2.034
1000.00 1.631 1.534
500.00 1.182 1.085
250.00 0.796 0.699
125.00 0.509 0.412
62.50 0.319 0.222
31.25 0.226 0.129
0.00 0.097 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant LONP1 and the recovery rates were calculated by comparing the measured value to the expected amount of LONP1 in samples.
Matrix Recovery range Average
serum(n=5) 86-99% 92%
EDTA plasma(n=5) 92-106% 99%
Heparin plasma(n=5) 80-95% 87%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of LONP1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-97% 96-105% 95-103% 95-103%
EDTA plasma(n=5) 84-98% 95-105% 88-102% 85-97%
Heparin plasma(n=5) 95-107% 87-98% 92-104% 82-96%