Products

Human SIGLEC14(Sialic acid binding Ig like lectin 14) ELISA Kit
ELK9378
Size: Price:
48 T $320.00
96 T $458.00

Overview

Product name: Human SIGLEC14(Sialic acid binding Ig like lectin 14) ELISA Kit
Reactivity: Human
Alternative Names: Sialic acid binding Ig like lectin 14; Sialic acid-binding Ig-like lectin 14; SIG14_HUMAN; Siglec 14; Siglec-14; SIGLEC14
Assay Type: Sandwich
Sensitivity: 13.6 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates and other biological fluids.
Assay Length: 3.5h
Research Area: Cell Biology
Uniprot ID: Q08ET2
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human SIGLEC14. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human SIGLEC14. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human SIGLEC14, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human SIGLEC14 in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (pg/mL) OD Corrected OD
2000.00 2.035 1.938
1000.00 1.572 1.475
500.00 1.128 1.031
250.00 0.871 0.774
125.00 0.525 0.428
62.50 0.317 0.220
31.25 0.175 0.078
0.00 0.097 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant SIGLEC14 and the recovery rates were calculated by comparing the measured value to the expected amount of SIGLEC14 in samples.
Matrix Recovery range Average
serum(n=5) 95-107% 101%
EDTA plasma(n=5) 96-107% 102%
Heparin plasma(n=5) 78-92% 85%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of SIGLEC14 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 95-102% 87-98% 79-96% 85-99%
EDTA plasma(n=5) 91-102% 89-98% 83-103% 88-97%
Heparin plasma(n=5) 93-103% 94-106% 93-106% 84-98%