Products

Human Histidyl-tRNA synthetase, cytoplasmic(HARS) ELISA Kit
ELK8405
Size: Price:
48 T $320.00
96 T $458.00

Overview

Product name: Human Histidyl-tRNA synthetase, cytoplasmic(HARS) ELISA Kit
Reactivity: Human
Alternative Names: FLJ20491; HRS; HisRS|histidine tRNA ligase 1; cytoplasmic|histidine translase|histidine-tRNA ligase
Assay Type: Sandwich
Sensitivity: 5.4 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Biosynthesis/Metabolism
Uniprot ID: P12081
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human HARS. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human HARS. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human HARS, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human HARS in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (pg/mL) OD Corrected OD
1000.00 2.266 2.170
500.00 1.639 1.543
250.00 1.193 1.097
125.00 0.928 0.832
62.50 0.576 0.480
31.25 0.364 0.268
15.63 0.230 0.134
0.00 0.096 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant HARS and the recovery rates were calculated by comparing the measured value to the expected amount of HARS in samples.
Matrix Recovery range Average
serum(n=5) 90-107% 98%
EDTA plasma(n=5) 87-99% 93%
Heparin plasma(n=5) 80-95% 87%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HARS and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 87-101% 86-97% 88-95%
EDTA plasma(n=5) 93-101% 86-92% 81-93% 79-95%
Heparin plasma(n=5) 85-94% 79-96% 98-105% 82-93%