Size: | Price: |
---|---|
48 T | $320.00 |
96 T | $458.00 |
Concentration (ng/mL) | OD | Corrected OD |
---|---|---|
50.00 | 2.035 | 1.948 |
25.00 | 1.643 | 1.556 |
12.50 | 1.073 | 0.986 |
6.25 | 0.892 | 0.805 |
3.13 | 0.518 | 0.431 |
1.57 | 0.365 | 0.278 |
0.79 | 0.208 | 0.121 |
0.00 | 0.087 | 0.000 |
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Matrix | Recovery range | Average |
---|---|---|
serum(n=5) | 85-99% | 92% |
EDTA plasma(n=5) | 78-92% | 85% |
Heparin plasma(n=5) | 78-90% | 84% |
Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
---|---|---|---|---|
serum(n=5) | 95-103% | 80-96% | 87-98% | 85-92% |
EDTA plasma(n=5) | 87-98% | 85-96% | 92-102% | 81-93% |
Heparin plasma(n=5) | 83-98% | 92-103% | 86-97% | 93-101% |