Products

Rat ADRa1A(Adrenergic Receptor Alpha 1A) ELISA Kit
ELK7453
Size: Price:
48 T $320.00
96 T $458.00

Overview

Product name: Rat ADRa1A(Adrenergic Receptor Alpha 1A) ELISA Kit
Reactivity: Rat
Alternative Names: ADR-A1A; ADRA1-A; ADRA1C; ADRA1L1; Alpha1AAR; Alpha 1a-Adrenoceptor
Assay Type: Sandwich
Sensitivity: 0.28 ng/mL
Standard: 50 ng/mL
Detection Range: 0.79-50 ng/mL
Sample Type: tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Cardiovascular biology;
Uniprot ID: P43140
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat ADRa1A. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat ADRa1A. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat ADRa1A, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat ADRa1A in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (ng/mL) OD Corrected OD
50.00 2.266 2.125
25.00 1.636 1.495
12.50 1.277 1.136
6.25 0.847 0.706
3.13 0.583 0.442
1.57 0.369 0.228
0.79 0.175 0.034
0.00 0.141 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant ADRa1A and the recovery rates were calculated by comparing the measured value to the expected amount of ADRa1A in samples.
Matrix Recovery range Average
serum(n=5) 84-97% 90%
EDTA plasma(n=5) 95-107% 101%
Heparin plasma(n=5) 77-95% 86%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ADRa1A and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 92-107% 83-99% 80-96% 91-101%
EDTA plasma(n=5) 90-97% 96-102% 91-103% 89-97%
Heparin plasma(n=5) 95-104% 87-96% 92-101% 82-90%