Size: | Price: |
---|---|
48 T | $320.00 |
96 T | $458.00 |
Concentration (ng/mL) | OD | Corrected OD |
---|---|---|
20.00 | 1.963 | 1.874 |
10.00 | 1.506 | 1.417 |
5.00 | 0.935 | 0.846 |
2.50 | 0.839 | 0.750 |
1.25 | 0.487 | 0.398 |
0.63 | 0.312 | 0.223 |
0.32 | 0.168 | 0.079 |
0.00 | 0.089 | 0.000 |
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Matrix | Recovery range | Average |
---|---|---|
serum(n=5) | 80-95% | 87% |
EDTA plasma(n=5) | 87-99% | 93% |
Heparin plasma(n=5) | 81-95% | 88% |
Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
---|---|---|---|---|
serum(n=5) | 85-94% | 97-106% | 79-91% | 90-99% |
EDTA plasma(n=5) | 85-102% | 81-96% | 87-105% | 83-92% |
Heparin plasma(n=5) | 88-97% | 86-92% | 79-103% | 89-97% |