Products

Mouse SLPI(Secretory Leukocyte Peptidase Inhibitor) ELISA Kit
ELK3222
Size: Price:
48 T $320.00
96 T $458.00

Overview

Product name: Mouse SLPI(Secretory Leukocyte Peptidase Inhibitor) ELISA Kit
Reactivity: Mouse
Alternative Names: ALK1; ALP; MPI; BLPI; HUSI; HUSI-I; WAP4; WFDC4; Antileukoproteinase; Seminal proteinase inhibitor; Mucus proteinase inhibitor; WAP four-disulfide core domain protein 4
Assay Type: Sandwich
Sensitivity: 6.3 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, urine, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Immune molecule;
Uniprot ID: P97430
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse SLPI. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse SLPI. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse SLPI, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse SLPI in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (pg/mL) OD Corrected OD
1000.00 1.985 1.888
500.00 1.783 1.686
250.00 1.251 1.154
125.00 0.878 0.781
62.50 0.585 0.488
31.25 0.363 0.266
15.63 0.226 0.129
0.00 0.097 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant SLPI and the recovery rates were calculated by comparing the measured value to the expected amount of SLPI in samples.
Matrix Recovery range Average
serum(n=5) 83-97% 90%
EDTA plasma(n=5) 80-97% 88%
Heparin plasma(n=5) 95-108% 101%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of SLPI and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 97-106% 79-91% 90-99%
EDTA plasma(n=5) 85-102% 81-96% 87-105% 83-92%
Heparin plasma(n=5) 88-97% 86-92% 79-103% 89-97%