Products

Mouse F12(Coagulation Factor XII) ELISA Kit
ELK3206
Size: Price:
48 T $320.00
96 T $458.00

Overview

Product name: Mouse F12(Coagulation Factor XII) ELISA Kit
Reactivity: Mouse
Alternative Names: FXII; HAF; Contact Factor; Hageman Factor
Assay Type: Sandwich
Sensitivity: 26.2 pg/mL
Standard: 4000 pg/mL
Detection Range: 62.5-4000 pg/mL
Sample Type: plasma
Assay Length: 3.5h
Research Area: Metabolic pathway;Hematology;
Uniprot ID: Q80YC5
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse F12. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse F12. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse F12, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse F12 in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (pg/mL) OD Corrected OD
4000.00 2.056 1.963
2000.00 1.731 1.638
1000.00 1.192 1.099
500.00 0.852 0.759
250.00 0.529 0.436
125.00 0.332 0.239
62.50 0.175 0.082
0.00 0.093 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant F12 and the recovery rates were calculated by comparing the measured value to the expected amount of F12 in samples.
Matrix Recovery range Average
serum(n=5) 82-94% 88%
EDTA plasma(n=5) 83-99% 95%
Heparin plasma(n=5) 94-105% 98%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of F12 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 81-94% 78-90% 83-95% 86-97%
EDTA plasma(n=5) 80-94% 90-99% 87-103% 83-96%
Heparin plasma(n=5) 88-102% 96-107% 89-103% 79-95%