Products

Mouse POMC(Proopiomelanocortin) ELISA Kit
ELK3032
Size: Price:
48 T $320.00
96 T $458.00

Overview

Product name: Mouse POMC(Proopiomelanocortin) ELISA Kit
Reactivity: Mouse
Alternative Names: POC; NPP; ProOMC; ACTH; Pro-OMC; Pro Opiomelanocortin; Corticotropin-lipotropin; Corticotropin; Adrenocorticotropic hormone
Assay Type: Competitive Inhibition
Sensitivity: 46.7 pg/mL
Standard: 10000 pg/mL
Detection Range: 156.25-10000 pg/mL
Sample Type: serum, plasma and other biological fluids
Assay Length: 2h
Research Area: Endocrinology;
Uniprot ID: P01193
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Mouse POMC protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse POMC. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse POMC in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (pg/mL) OD Corrected OD
10000.00 0.183
5000.00 0.332
2500.00 0.596
1250.00 0.895
625.00 1.168
312.50 1.457
156.25 1.769
0.00 2.028

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant POMC and the recovery rates were calculated by comparing the measured value to the expected amount of POMC in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 94%
EDTA plasma(n=5) 84-95% 88%
Heparin plasma(n=5) 82-97% 92%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of POMC and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 87-101% 92-102% 81-93%
EDTA plasma(n=5) 85-97% 87-96% 86-98% 91-103%
Heparin plasma(n=5) 85-92% 95-103% 97-105% 93-102%