Products

Human LRG1(Leucine Rich Alpha-2-Glycoprotein 1) ELISA Kit
ELK2686
Size: Price:
48 T $320.00
96 T $458.00

Overview

Product name: Human LRG1(Leucine Rich Alpha-2-Glycoprotein 1) ELISA Kit
Reactivity: Human
Alternative Names: A2GL ; HMFT1766 ; Leucine rich alpha 2 glycoprotein ; Leucine-rich alpha-2-glycoprotein 1 ;  LRG ; LRG1
Assay Type: Sandwich
Sensitivity: 1.37 ng/mL
Standard: 200 ng/mL
Detection Range: 3.13-200 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Tumor immunity;Infection immunity;
Uniprot ID: P02750
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human LRG1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human LRG1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human LRG1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human LRG1 in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (ng/mL) OD Corrected OD
200.00 2.045 1.941
100.00 1.577 1.473
50.00 1.198 1.094
25.00 0.797 0.693
12.50 0.532 0.428
6.25 0.345 0.241
3.13 0.249 0.145
0.00 0.104 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant LRG1 and the recovery rates were calculated by comparing the measured value to the expected amount of LRG1 in samples.
Matrix Recovery range Average
serum(n=5) 88-102% 95%
EDTA plasma(n=5) 83-96% 89%
Heparin plasma(n=5) 92-107% 99%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of LRG1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 89-102% 92-101% 88-102% 87-102%
EDTA plasma(n=5) 85-92% 79-96% 89-101% 85-97%
Heparin plasma(n=5) 86-101% 86-101% 87-96% 92-105%