Products

Human CKMT1A(Creatine Kinase, Mitochondrial 1A) ELISA Kit
ELK1905
Size: Price:
48 T $320.00
96 T $458.00

Overview

Product name: Human CKMT1A(Creatine Kinase, Mitochondrial 1A) ELISA Kit
Reactivity: Human
Alternative Names: CKMT; CKMT1-A; Mia-CK; U-MtCK; Creatine kinase U-type, mitochondrial; Ubiquitous mitochondrial creatine kinase; Acidic-type mitochondrial creatine kinase
Assay Type: Sandwich
Sensitivity: 0.54 ng/mL
Standard: 100 ng/mL
Detection Range: 1.57-100 ng/mL
Sample Type: Serum, plasma, tissue homogenates and other biological fluids.
Assay Length: 3.5h
Research Area: Cardiovascular biology;
Uniprot ID: P12532
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CKMT1A. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CKMT1A. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CKMT1A, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CKMT1A in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (ng/mL) OD Corrected OD
100.00 2.075 1.967
50.00 1.502 1.394
25.00 1.128 1.020
12.50 0.928 0.820
6.25 0.539 0.431
3.13 0.387 0.279
1.57 0.226 0.118
0.00 0.108 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant CKMT1A and the recovery rates were calculated by comparing the measured value to the expected amount of CKMT1A in samples.
Matrix Recovery range Average
serum(n=5) 80-95% 87%
EDTA plasma(n=5) 95-107% 101%
Heparin plasma(n=5) 80-93% 86%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CKMT1A and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-99% 98-106% 86-99% 78-95%
EDTA plasma(n=5) 89-99% 83-99% 98-105% 96-101%
Heparin plasma(n=5) 85-100% 84-99% 85-97% 88-102%